Sign In | Join Free | My benadorassociates.com |
|
Brand Name : Eaton
Model Number : ups system
Certification : CE, RoHS
Place of Origin : Hubei, China
MOQ : 1 Piece
Price : Negotiable
Payment Terms : T/T, L/C
Supply Ability : 10000 Pieces/Month
Delivery Time : within 10 days of payment
Packaging Details : carton & PVC packaging
UPS bypass : Automatic
Dimensions : See models table
Diagnostics : Full system self-test
LEDs : 4 status-indicating LEDs
Topology : True online, 2 conversion
Rail kit : Included with all rackmount units
EATON 9130 Uninterruptible Power Supply System Rackmount/Tower UPS
Specifications
General
User interface | Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish |
LEDs | Four status-indicating LEDs |
Topology | True online, double-conversion |
Diagnostics | Full system self-test |
UPS bypass | Automatic bypass |
Dimensions | See models table |
Rail kit | Included with all rackmount units |
Electrical Input | |
Nominal voltage | 120V, 220–240V |
Voltage range | 120V: 90–138 Vac; 230V: 160–276 Vac |
Power drawn from UPS | 700: 3.0A @230V, 5.8A @120V; 1000: 4.3A @230V, 8.3A @120V; 1500: 6.5A @230V, 12.5A @120V; 2000: 8.7A @230V, 16.6A @120V; 3000: 13A @230V, 25A @ 120V; 5000: 21.7A @230V; 6000: 26A @230V |
Dedicated circuit breaker rating UPS input rating | 120V: 700–1500 VA: 15A; 2000 VA: 20A; 2500–3000 VA: 30A |
230V: 700–2000 VA: 10A; 3000 VA: 16A; 5000 VA: 24A; 6000 VA: 32A; | |
Frequency | 50/60 Hz |
Frequency range | 45–65 Hz |
Electrical Output | |
Power factor | 0.9 |
On utility voltage | ±3% of nominal regulation |
On battery voltage | ±3% of nominal regulation |
Efficiency | >95% in high-efficiency mode; >86% in online mode |
Frequency regulation | ±3% Hz online |
Load crest factor | 3 to 1 |
Battery | |
Battery type | VRLA 12V/9 Ah (both internal and external) |
Battery runtime | See runtime table |
Battery replacement | Hot-swappable internal and external batteries |
Start-on-battery | Allows start of UPS without utility input |
Description | Part Number Rating Input connection Output recetacles Dimensions Weight, kg | |||||
Tower Models 230V, 50/60Hz | ||||||
9130-700i | 103006433-6591 | 700/630 | C14 | (6) C13 | 230 x 160 x 350 | 12.2 |
9130-1000i | 103006434-6591 | 1000/900 | C14 | (6) C13 | 230 x 160 x 380 | 14.5 |
9130-1500i | 103006435-6591 | 1500/1350 | C14 | (6) C13 | 230 x 160 x 430 | 19.0 |
9130-2000i | 103006436-6591 | 2000/1800 | C14 | (8) C13, (1) C19 | 325 x 214 x 410 | 34.5 |
9130-3000i | 103006437-6591 | 3000/2700 | C20 | (8) C13, (1) C19 | 325 x 214 x 410 | 34.5 |
9130-5000i | 103007841-6591 | 5000/4500 | Hardwire | Hardwire | 574 x 244 x 542 | 75.5 |
9130-6000i | 103007842-6591 | 6000/5400 | Hardwire | Hardwire | 574 x 244 x 542 | 75.5 |
Tower Models 120V, 50/60Hz | ||||||
9130-700L | 103006426-6591 | 700/630 | 5-15P | (6) 5-15R | 230 x 160 x 350 | 12.2 |
9130-1000L | 103006427-6591 | 1000/900 | 5-15P | (6) 5-15R | 230 x 160 x 380 | 14.5 |
9130-1500L | 103006428-6591 | 1500/1350 | 5-15P | (6) 5-15R | 230 x 160 x 430 | 19.0 |
9130-2000L | 103006429-6591 | 2000/1800 | 5-20P | (1) L5-20R, (4) 5-20R | 325 x 214 x 410 | 34.5 |
9130-3000L | 103006430-6591 | 3000/2700 | L5-30P | (4) 5-20R, (1) L5-30R | 325 x 214 x 410 | 34.5 |
Tower Extended Battery Modules | ||||||
9130EBM 36 (1kVA) | 103006438-6591 | NA | NA | NA | 230 x 160 x 380 | 18.5 |
9130EBM 48 (1.5kVA) | 103006439-6591 | NA | NA | NA | 230 x 160 x 430 | 24.3 |
9130EBM 96 (2/3kVA) | 103006440-6591 | NA | NA | NA | 325 x 214 x 410 | 50.0 |
9130 ebm 240 (5/6kVA) | 103007843-6591 | NA | NA | NA | 574 x 244 x 542 | 111.0 |
Rack Models 230V, 50/60Hz | ||||||
9130-1000iRM 2U | 103006455-6591 | 1000/900 | C14 | (6) C13 | 86.5 x 438 x 450 | 16.0 |
9130-1500iRM 2U | 103006456-6591 | 1500/1350 | C14 | (6) C13 | 86.5 x 438 x 450 | 19.0 |
9130-2000iRM 2U | 103006457-6591 | 2000/1800 | C14 | (8) C13, (1) C19 | 86.5 x 438 x 600 | 29.0 |
9130-3000iRM 2U | 103006463-6591 | 3000/2700 | C20 | (8) C13, (1) C19 | 86.5 x 438 x 600 | 29.5 |
Rack Models 120V, 50/60Hz | ||||||
9130-1000RM 2U | 103006448-6591 | 1000/900 | 5-15P | (6) 5-15R | 87 x 438 x 450 | 16.0 |
9130-1500RM 2U | 103006449-6591 | 1500/1350 | 5-15P | (6) 5-15R | 87 x 438 x 450 | 19.5 |
9130-2000RM 2U | 103006450-6591 | 2000/1800 | 5-20P | (6) 5-20R, (1) L5-20R | 87 x 438 x 600 | 29.0 |
9130-3000RM 2U | 103006452-6591 | 3000/2700 | L5-30P | (6) 5-20R, (1) L5-30R | 87 x 438 x 600 | 29.5 |
Rack Extended Battery Modules | ||||||
9130RM EBM 36 (1kVA) | 103006458-6591 | NA | NA | NA | 86.5 x 438 x 450 | 22.1 |
9130RM EBM 48 (1.5kVA) | 103006459-6591 | NA | NA | NA | 86.5 x 438 x 450 | 28.1 |
9130RM EBM 72 (2/3kVA) | 103006460-6591 | NA | NA | NA | 86.5 x 438 x 600 | 41.1 |
Functions
Remote monitoring. The 9130 comes complete with the Eaton Software Suite CD including SNMP-compatible power man- agement software providing control and visibility over all your UPS systems. For example, you can establish a prioritized shutdown of network devices and client/server applications, test all networked UPS systems from one node, and stay
informed of power problems by email.
Choice of connectivity options. Connectivity options are avail- able for almost any networking environment. The standard unit comes with USB and RS-232 serial communication ports. You can customize your UPS by adding communication cards options that will allow to:
•Integrate the UPS to SNMP based Network Management Systems with a Web/SNMP card and manage it through standard web browsers
•Monitor and shut down multiple servers with different operating systems
•Send relay-contact alarm notifications to remote security systems
Complementary options
You can complement your 9130 with several options, among which:
•A maintenance bypass for easy replacement of the UPS without powering down critical systems
•Power distribution units streamline the distribution of power throughout a data center, rack or enclosure
One platform, two form factors, dozens of choices. Up to 3000 VA of UPS power is packed into only 2U of rack space. The
tower option is about the size of a modern, compact PC.
Maximum availability for critical systems
Stronger, longer battery life. Eaton Advanced Battery Mana- gement (ABM) technology uses sophisticated sensing circuitry and an innovative three-stage charging technique, that con- stantly monitors the battery charging status, and as a result only recharges when necessary, so ultimately the battery ex- periences less corrosion and battery service life is prolonged by up to 50%.
The 9130 provides up to 60 days’ notice of the end of useful battery service life. You have ample time to hot-swap batteries without ever having to shut down connected equipment.
Battery runtime for minutes or hours. During a power outage, internal batteries in the 9130 keep loads running long enough to gracefully shut down systems. Add more runtime at any
time, with up to four external hot-swappable battery modules to run systems for hours if necessary.
Maximum battery runtime for critical equipments. Using Load Segment Control, you can manage scheduled shutdowns and sequential startups of protected loads. During a power outage, you could shut down power to non-critical devices, thereby extending battery backup time available for critical devices.
You can also use this feature to remotely re-boot locked-up equipment.
Visibility, control and management from anywhere
Continous monitoring for premium availability. The 9130 continually monitors voltage, temperature, internal element functions, battery health, battery state-of-charge and runtime remaining. If the UPS detects a potential problem with any
of these measures, it sends alarms or takes corrective action, with no interruption in power. At the end of an alarm condi- tion, the 9130 automatically reverts from bypass to normal operation.
Local UPS status at a glance. An on-site user can configure and monitor many features of the 9130 using a large, bright, backlit display with easy navigation—available in multiple lan- guages. LEDs provide at-a-glance insight into system status.
Rackmount Tower EATON 9130 Uninterruptible Power Supply System Images |